Fire ladders using extruded fiberglass channel rail construction and aluminum rungs welded to aluminum blocks and riveted to the fiberglass side rails.
All fiberglass ladders are non-conductive for single phase 110 volt service with a maximum of 30,000 volts only, dependent upon conditions.
See our Fiberglass Price List for current pricing.
Specifications | ||||
---|---|---|---|---|
SERIES YGE-2 2-SECTION EXTENSION | ||||
Size | Closed Length | Width | Banking Thickness | Weight* |
16' | 10' .5" | 23" | 7" | 80 lbs |
20' | 12' 3.5" | 23" | 7" | 95 lbs |
24' | 14' 3.5" | 23" | 7" | 110 lbs |
28' | 16' 3.5" | 23" | 7" | 126 lbs |
30' | 17' 10.5" | 23" | 7" | 140 lbs |
35' | 20' 3.5" | 23" | 7" | 160 lbs |
SERIES YGE-3 3-SECTION EXTENSION | ||||
Size | Closed Length | Width | Banking Thickness | Weight* |
28' | 12' 11.5" | 26.5" | 9.5" | 162 lbs |
30' | 13' 3.5" | 26.5" | 9.5" | 170 lbs |
35' | 15' 3.5" | 26.5" | 9.5" | 195 lbs |
All dimensions listed are N.F.P.A. Design Verification Standards. Variations occur in each product of approximately +/- .125" due to the type of rivets, nuts, bolts etc. used. If you require precise dimensions, please call our office and request a copy of our current field dimension sheets. | ||||
* Weight listed is actual weight of product only. For shipping purposes, please call our office for packaged weight before obtaining freight estimates. |
We suggest all Fire Departments refer to both the National Fire Protection Association (N.F.P.A.) and the International Fire Service Training Association (I.F.S.T.A.) for complete and proper practices and usage of Fire Service ladders.